A Comparison of Chromogen Test Strip (Chemstrip bG) and Serum Glucose Values in Newborns

Paul C. Holtrop, MD; Kimberly A. Madison, RNC; Frederick L. Kiechle, MD, PhD; Raymond E. Karcher, PhD; Daniel G. Batton, MD
Am J Dis Child. 1990;144(2):183-185. doi:10.1001/archpedi.1990.02150260063029.
Text Size: A A A
Published online

• Although glucose oxidase-peroxidase chromogen test strips are frequently used to estimate serum glucose values in newborns, previous studies have not evaluated multiobserver variability of test strip readings and have included few infants with hypoglycemia. We compared values of 272 samples of serum glucose with values simultaneously obtained by chromogen test strips (Chemstrip bG) in newborns. The diagnostic sensitivity of a chromogen test strip less than 2.2 mmol/L for predicting a serum glucose level less than 1.9 mmol/L was 86% (95% confidence interval [CI], 75% to 94%), with 78% specificity (95% CI, 73% to 84%). The positive predictive value in our specimens, with a 21% prevalence of serum glucose levels less than 1.9 mmol/L, was 52% (95% CI, 41% to 62%), with a negative predictive value of 95% (95% CI, 91% to 100%).Fifty-eight of our serum glucose values were less than 1.9 mmol/L and the levels obtained by chromogen test strip were greater than or equal to 2.2 mmol/L in 8 of these cases. Review of these 8 cases showed that a delay in performing the laboratory glucose oxidase serum glucose could account for the discrepancy in 2 cases. Chromogen test strips are readily available and easy to use, but more sensitive, specific, accurate, and precise methods of serum glucose screening in newborns are needed.

(AJDC. 1990;144:183-185)

Topics

Sign in

Create a free personal account to sign up for alerts, share articles, and more.

Purchase Options

• Buy this article
• Subscribe to the journal

Figures

Tables

References

Correspondence

CME
Meets CME requirements for:
Browse CME for all U.S. States
Accreditation Information
The American Medical Association is accredited by the Accreditation Council for Continuing Medical Education to provide continuing medical education for physicians. The AMA designates this journal-based CME activity for a maximum of 1 AMA PRA Category 1 CreditTM per course. Physicians should claim only the credit commensurate with the extent of their participation in the activity. Physicians who complete the CME course and score at least 80% correct on the quiz are eligible for AMA PRA Category 1 CreditTM.
Note: You must get at least of the answers correct to pass this quiz.
You have not filled in all the answers to complete this quiz
The following questions were not answered:
Sorry, you have unsuccessfully completed this CME quiz with a score of
The following questions were not answered correctly:
Commitment to Change (optional):
Indicate what change(s) you will implement in your practice, if any, based on this CME course.
Your quiz results:
The filled radio buttons indicate your responses. The preferred responses are highlighted
For CME Course: A Proposed Model for Initial Assessment and Management of Acute Heart Failure Syndromes
Indicate what changes(s) you will implement in your practice, if any, based on this CME course.
Submit a Comment

Multimedia

Some tools below are only available to our subscribers or users with an online account.

Sign in

Create a free personal account to sign up for alerts, share articles, and more.

Purchase Options

• Buy this article
• Subscribe to the journal

Related Content

Customize your page view by dragging & repositioning the boxes below.

Jobs
brightcove.createExperiences();