0
Article | Journal Club

Sucking Improvement Following Blood Transfusion for Anemia of Prematurity

Ruben Bromiker, MD; Yifat Kasinetz, MD; Michael Kaplan, MB, ChB; Cathy Hammerman, MD; Michael Schimmel, MD; Barbara Medoff-Cooper, PhD
Arch Pediatr Adolesc Med. 2012;166(10):897-901. doi:10.1001/archpediatrics.2012.676.
Text Size: A A A
Published online

Objective  To determine whether correction of anemia of prematurity by packed red blood cell transfusion improves sucking.

Design  Nonexperimental intervention study.

Setting  Neonatal intensive care unit of Shaare Zedek Medical Center, Jerusalem, Israel, between July 23, 2006, and December 16, 2007.

Patients  Thirty-six neonates at a gestational age of 34 weeks or younger, feeding orally, who developed anemia of prematurity.

Intervention  Packed red blood cell transfusion, 15 mL/kg.

Main Outcome Measures  Change in sucking parameters recorded with the Kron Nutritive Sucking Apparatus for 5 minutes and ingested volume, prior to and 1 to 2 days after intervention.

Results  The mean (SD) gestational age was 30.1 (2.1) weeks, and the mean (SD) birth weight was 1436 (45) g. At the time of the study, the mean (SD) postnatal age was 46 (26) days, the mean (SD) weight was 2311 (36) g, and the mean (SD) hematocrit was 26.7% (2.6%). Overall, there was no change in the number of sucks, number of bursts, or maximum negative pressure generated. Daily weight gain increased after transfusion (mean [SD] weight gain, 30.9 [10.0] g before transfusion vs 36.5 [13.0] g after transfusion; P = .02). The babies were then stratified into those below the median number of sucks (109 sucks) before transfusion (poor feeders) and those at or above the median (better feeders). In the former subgroup only, changes from before transfusion to after transfusion were found in the number of sucks (mean [SD] sucks, 73.4 [29.5] vs 108.9 [53.3], respectively; P = .006; mean [SD] sucks per burst, 3.4 [1.4] vs 4.9 [2.8], respectively; P = .01) and volume consumed (mean [SD] volume, 17.1 [9.8] mL vs 23.2 [12.8] mL, respectively; P = .004).

Conclusions  Correction of anemia of prematurity with blood transfusion improved sucking and volume ingested in premature infants who were poor feeders prior to the transfusion. It also enhanced overall weight gain.

Figures in this Article

Sign In to Access Full Content

Don't have Access?

Register and get free email Table of Contents alerts, saved searches, PowerPoint downloads, CME quizzes, and more

Subscribe for full-text access to content from 1998 forward and a host of useful features

Activate your current subscription (AMA members and current subscribers)

Purchase Online Access to this article for 24 hours

Figures

Place holder to copy figure label and caption
Grahic Jump Location

Figure. Sucking device. The block with the built-in transducer is inserted between the bottle and the nipple. The cable connects to the digitalizer.

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

References

Correspondence

CME


You need to register in order to view this quiz.
NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s “Cited By” API will populate this tab (http://www.crossref.org/citedby.html).
Submit a Comment

Some tools below are only available to our subscribers or users with an online account.

Sign In to Access Full Content

Related Content

Customize your page view by dragging & repositioning the boxes below.

See Also...
Articles Related By Topic
Related Topics
Jobs